1. Configure who should receive email event notifications. The class option lets you simply
choose a class of events for the specified recipients. The event option lets you add
specified events to the info event class. The detail option only applies to process crash
events; by default it is enabled.
email notify recipient <email_address> [class {[failure] [info]}] [detail]
email notify event <event_name>
2. Set domain (default is configured ip domain-list), mailhub (SMTP server), mailhub-
port, return address, and include or exclude (with no) the return host in email notifications
(default is include).
email domain {<hostname> | <IP_address>}
email mailhub {<hostname> | <IP_address>}
email malhub-port <port_number>
email return-addr <username>
email return-host
3. Disable or enable event emails sent to Juniper Networks for certain pre-configured events;
default is enabled. Use no email autosupport enable to disable.
email autosupport enable
4. Manage undeliverable emails. Use cleanup max-age to set when to permanently delete.
dead-letter enable [cleanup max-age <duration>]
5. Send a test email to all the configured email notify recipients.
email send-test
6. To verify configurations:
show email
Example:
test-vos (config) # email notify recipient bobo@example.com
test-vos (config) # email notify event disk-io-high
test-vos (config) # email domain example.com
test-vos (config) # email mailhub mailgate1.example.com
test-vos (config) # email mailhub-port 22
test-vos (config) # email return-addr support@example.com
test-vos (config) # email return-host
test-vos (config) # email autosupport enable
test-vos (config) # email dead-letter enable
test-vos (config) # show email
Mail hub:
Mail hub port:
Domain:
Return address: support@example.com
Include hostname in return address: yes
Dead Letter settings:
Save dead.letter files: yes
Dead letter max-age: (none)
Failure events for which emails will be sent:
process-crash: A process in the system has crashed
smart-warning: Smartd warnings
unexpected-shutdown: Unexpected system shutdown
Informational events for which emails will be sent:
liveness-failure: A process in the system was detected as hung
Configuring and Using Media Flow Controller Logs and Alarms
Note!
The mailhub option must be sent for notifications to work.