Primary Processor Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Test Error Codes

100-199, Primary Processor Test Error Codes

The 100 series of diagnostic error codes identifies failures with processor and system
board functions. Corrective action may require replacing system boards or processor
assemblies.
Table B-2: Primary Processor Test Error Codes
Error Code
Description
101-XX
CPU test failed
103-XX
DMA page registers test
failed
104-XX
Interrupt controller master
test failed
105-XX
Port 61 error occurred
106-XX
Keyboard controller
self-test failed
107-XX
CMOS RAM test failed
108-XX
CMOS interrupt test failed
109-XX
CMOS clock load data test
failed
110-XX
Programmable timer load
data test failed
111-XX
Refresh detect test failed
113-XX
Protected mode test failed
114-XX
Speaker test failed
116-XX
Cache test failed
B-2
Recommended Action
Replace the processor and retest.
For error codes 103-XX through 106-XX, replace the
processor and retest.
The following steps apply to error codes 107-XX
through 109-XX.
1.
Replace the battery/clock module and retest.
2.
Replace the system board and retest.
For error codes 110-XX through 113-XX, replace the
system board and retest.
1.
Check the speaker connection and retest.
2.
Replace the speaker and retest.
3.
Replace the system board and retest.
Replace the system board and retest.
HP Servers Troubleshooting Guide
continued

Advertisement