Windows® Event Log processor error codes

Message ID: 4137

Severity: Error
Description: The processor in slot X, socket X has corrected an excessive number of internal errors. The system
will continue to operate.
Action:
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.

Message ID: 4140

Severity: Warning
Description: The system is operating with a heterogeneous processor environment.
Action: None

Message ID: 4141

Severity: Warning
Description: Only X out of the X installed processors have been started by the operating system. The system
will continue to operate.
Action: Confirm that the license agreement in use supports all of the installed processors.

Message ID: 4169

Severity: Warning
Description: The processor in slot X, socket X has corrected an excessive number of internal errors. The system
will continue to operate.
Action:
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.

Message ID: 4190

Severity: Error
Before removing or replacing any processors, be sure to follow the guidelines
Before removing or replacing any processors, be sure to follow the guidelines