ADU Error Messages
Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Identify controller data did not
match with NVRAM.
Identify logical drive data did
not match with NVRAM.
Insufficient adapter resources
Inter-controller link connection
could not be established
Less than 75% batteries at
sufficient voltage
D-10
Description
The controller identification
data from the array controller
does not match with the
information stored in NVRAM.
This can occur if new,
previously configured drives
are placed in a system that
has also been previously
configured. It can also occur if
the firmware on the controller
has been upgraded and the
server setup utility was not.
The identify unit data from the
array controller does not
match with the information
stored in NVRAM. This can
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured.
The adapter does not have
sufficient resources to perform
posted-write operations to the
array accelerator board. Drive
rebuild may be occurring.
Unable to communicate over
the link connecting the
redundant controllers.
The operation of the array
accelerator board has been
disabled due to less than 75%
of the battery packs being at
the sufficient voltage level.
continued
Recommended Action
Run the Inspect Utility to check
the controller identification
data. If the firmware version
field is the only difference
between the controller and
NVRAM data, this is not a
problem. Otherwise run the
server setup utility.
Run the server setup utility to
configure the controller and
NVRAM.
Operate the system without
the array accelerator board
until the drive rebuild
completes.
Be sure that both controllers
are using the same hardware
and firmware revisions. If one
controller failed, replace it.
Allow sufficient time for the
batteries to recharge (36
hours). If the batteries have
not recharged after 36 hours,
replace the array accelerator
board.
HP Servers Troubleshooting Guide