HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 220

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-12: 1600 Series POST Error Messages
Error Code
1611-Front CPU
Fan X not present
1611-I/O Fan failure
detected
1611-I/O Fan not
present
1611-I/O Fan (Fan X)
failure detected
1611-I/O Slot Fan X
not present
1611-I/O Slot CPU
Fan X Failure
Detected
1611-Power Supply
Fan X failure detected
C-40
Audible
Probable Source of
Beeps
Problem
None
Required fan not
installed.
None
Required fan not
spinning.
None
Required fan not
installed.
2 short
I/O fan has failed.
None
Required fan not
installed.
None
Required fan not
spinning.
None
Required fan not
spinning.
continued
Action
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
HP Servers Troubleshooting Guide
continued

Advertisement