POST Error Messages

1800 Series POST Error Messages

Table C-14: 1800 Series POST Error Messages
Error Code
1800 - Temperature
Alert
1801-Microcode
Patch Error
Missing or Invalid
Processor Microcode
Patch. Please contact
Compaq Computer
Corporation for a new
ROM BIOS to support
the new Processor
Stepping
C-70
Audible
Probable Source of
Beeps
Problem
None
System has exceeded
allowable temperature
thresholds.
None
The newly installed
processor is not
supported by the current
system ROM.
Action
1.
Turn system off and allow
it to cool.
2.
Check fans for proper
airflow and obstructions.
3.
Check fans for proper
operation.
4.
Analyze ambient
temperature in which the
server is currently
operating, and compare
to server-specific user
documentation
recommendations.
5.
Adjust as needed before
restarting the server.
Upgrade the system ROM or
reinstall the original
processor.