Table C-12: 1600 Series POST Error Messages
Error Code
1615- Power Supply
Failure
1615-Power Supply
Failure, Power Supply
Unplugged, or Power
Supply Fan Failure in
Bay X.
1616- Power Supply
Configuration Failure
1617-Fan controller
not responding
1617-Fan controller
not responding.
System halted.
1617-I/O Fan
controller not
responding.
System halted.
1617-CPU Fan
controller not
responding.
System halted.
1618-PCI slots
powered down. Check
PCI Hot-Plug enabler
connectors.
1618- PCI slots
powered down.
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
Power supply has failed.
None
Power supply has failed.
None
Power supply is
improperly configured.
2 short
Fan controller failure
detected.
2 short
Fan controller failure
detected.
2 short
I/O fan controller failure
detected.
2 short
CPU fan controller failure
detected.
None
PCI Hot Plug enabler is
missing or failed.
None
PCI Hot plug enabler is
missing or failed.
continued
Action
Reseat power supply firmly.
-Or-
Replace power supply as
soon as possible.
Reseat power supply firmly.
-Or-
Replace power supply as
soon as possible.
Run the server setup utility
and correct.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace missing or
failed assembly.
Check and replace missing or
failed assembly.
POST Error Messages
continued