Series Post Error Messages - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages

200 Series POST Error Messages

Table C-4: 200 Series POST Error Messages
Error Code
201-Memory Error
201-Memory Error
The memory test
performed during
startup failed.
Removing and
replacing memory
modules can isolate
the faulty memory.
Also verify that the
memory modules are
installed correctly.
202-Memory Type
Mismatch
203-Memory Address
Error
205-Cache Memory
error
C-14
Audible
Probable Source of
Beeps
Problem
None
RAM failure detected.
None
RAM failure detected.
2 short
An incompatible memory
module is installed in the
system.
None
RAM failure detected.
2 short
A memory module is
malfunctioning.
Action
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed assembly as instructed.
Compare part numbers from
installed memory modules
with those listed in your
server-specific user
documentation.
If not listed, the memory
modules are incompatible and
should be replaced or
removed.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace or
remove malfunctioning
memory module as indicated.
HP Servers Troubleshooting Guide
continued