Table C-4: 200 Series POST Error Messages
Error Code
213-Processor
Disabled, Processor X
214-DC-DC Converter
Failed
214-Memory Device
Failure. Error Code:X
Memory Module
DIMM:Y
214-Processor board
PPM failed
214-Processor PPM
Failed, Module X.
214-Processor PPM
Failed, Processor Bus
X
215-Non-functioning
Voltage Regulator
Module for Processor
X
215-Processor PPM
not installed, module
216-Processor board
PPM has lost
redundancy
216-Processor PPM
has lost Redundancy,
Module X.
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
The PPM and voltage
regulator module (VRM)
for processor X is not
installed correctly.
None
PPM failed.
2 short
A memory module has
failed.
None
Missing or failed PPM.
None
Indicated PPM failed.
None
A processor PPM has
failed or is missing. The
failed PPM is located on
a disabled processor bus.
None
PPM (DC-DC converter)
failed or lost redundancy.
None
A processor has been
installed without its
corresponding PPM.
None
Indicated PPM has lost
redundancy.
None
Indicated PPM has lost
redundancy.
continued
Action
Check whether the PPM and
VRM is installed and correctly
seated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed memory module as
indicated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Install
assembly as indicated.
Run Diagnostics. Replace
failed assembly as indicated.
Run Diagnostics. Replace
failed assembly as indicated.
POST Error Messages