Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Storage enclosure on SCSI
bus X has a cabling error (bus
disabled).
SOLUTION: The SCSI
controller has an internal and
external cable attached to the
same bus. Please disconnect
the internal or external cable
from the controller. If this
controller supports multiple
buses, the cable disconnected
can be reattached to an
available bus.
Storage enclosure on SCSI
bus X indicated a door alert.
SOLUTION: Be sure that the
storage enclosure door is
closed or the side panel is
properly installed.
Storage enclosure on SCSI
bus X indicated a power
supply failure.
SOLUTION: Replace the
power supply.
HP Servers Troubleshooting Guide
Description
The current cabling
configuration is not supported.
The side panel of the external
storage unit is open.
A power supply in the external
storage unit has failed.
ADU Error Messages
continued
Recommended Action
Refer to your server-specific
user documentation for cabling
guidelines, and reconfigure as
indicated.
Be sure that the side panel of
the storage unit is securely
closed.
Replace the power supply.
continued
D-17