ADU Error Messages
Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Accelerator board not detected
Accelerator error log
Accelerator parity read errors:
X
Accelerator parity write errors:
X
Accelerator status: Cache was
automatically configured
during last controller reset
Accelerator status: Data in the
cache was lost due to some
reason other than the battery
being discharged.
D-2
Description
Array controller did not detect
a configured array accelerator
board.
List of the last 32 parity errors
on transfers to or from the
memory on the array
accelerator board. Displays
starting memory address,
transfer count, and operation
(read and write).
Number of times that read
memory parity errors were
detected during transfers from
memory on array accelerator
board.
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
Cache board was replaced
with one of a different size.
Data in cache was lost, but not
because of the battery being
discharged.
Recommended Action
Install an array accelerator
board on an array controller. If
an array accelerator board is
installed, check for proper
seating on the array controller
board.
If there are many parity errors,
you may need to replace the
array accelerator board.
If there are many parity errors,
you may need to replace the
array accelerator board.
If there are many parity errors,
you may need to replace the
array accelerator board.
Normal operations should
continue.
Check to be sure that the array
accelerator is properly seated.
If the error continues, you may
need to replace the array
accelerator.
HP Servers Troubleshooting Guide
continued