Table C-4: 200 Series POST Error Messages
Error Code
220-cache accelerator
Slot X Initialization
Failed. System Halted
221-Power Fault On
Processor Bus X
222-Processor bus
disabled, Processor
Bus X.
252-Invalid Memory
SPD reading
253-Invalid Memory
Cycle Time reading
254-Invalid Memory
Revision Code
255-Invalid Memory
CL2 Support
256-Invalid Memory
TRP reading
257-Invalid Memory
TRRD reading
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
Cache accelerator in slot
X improperly installed or
bad.
None
A Processor Power
Module (PPM) on
indicated bus is in a
failed state.
None
Hardware or BIOS have
disabled a processor bus.
None
Failed or incompatible
DIMM.
None
Failed or incompatible
DIMM.
None
Failed or incompatible
DIMM.
None
Failed or incompatible
DIMM.
None
Failed or incompatible
DIMM.
None
Failed or incompatible
DIMM.
continued
Action
Check cache accelerator
installation and if properly
installed, replace.
Run Diagnostics. Replace
failed assembly as indicated.
Refer to actions for
accompanying error
messages.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
Be sure that the specified
DIMM meets the
requirements for supported
DIMMs. Replace DIMM.
POST Error Messages
continued
C-23