POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1786-Slot 1 Drive
Array Recovery
Needed. The
following SCSI
drive(s) need
Automatic Data
Recovery: SCSI
Port Y: SCSI ID Z
Select F1 to continue
with recovery of data
to drive. Select F2 to
continue without
recovery of data to
drive.
-Or-
Slot 1 Drive Array
Recovery Needed.
Automatic Data
Recovery Previously
Aborted! The
following SCSI
drive(s) need
Automatic Data
Recovery: SCSI
Port Y: SCSI ID Z
Select F1 to retry
Automatic Data
Recovery to drive.
Select F2 to continue
without starting
Automatic Data
Recovery.
C-64
Audible
Probable Source of
Beeps
Problem
None
System in Interim Data
Recovery mode.
Previously-failed or
replacement drive has
not yet been rebuilt.
continued
Action
Press the F1 key to allow
Automatic Data Recovery to
begin. Data is automatically
restored to drive X when the
drive has been replaced or
seems to be working.
-Or-
1.
Press the F2 key for the
system to continue to
operate in the Interim
Data Recovery mode.
The previously aborted
version of the 1786
POST message is
displayed if the previous
rebuild attempt was
aborted for any reason.
2.
Run Array Diagnostic
Utility (ADU) for more
information.
If the replacement drive
was failed, try using
another replacement
drive.
-Or-
If rebuild was aborted
due to a read error from
another physical drive in
the array, back up all
readable data on the
array, run Diagnostics
Surface Analysis, and
then restore your data.