HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 119

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Diagnostic Tools
Table 4-1: Event Messages
Event Message
PCI Bus Error
PCI Bus Error (Slot X,
Bus Y, Device Z,
Function x)
Automatic Server Recovery-2 (ASR-2)
ASR Lockup Detected:
Cause
Power Subsystem
System Power Supply
Failure (Power
Supply X)
System Power
Supplies Not
Redundant
Real-Time Clock
Battery Failing
A CPU Power Module
(System Board,
Socket X)
A CPU Power Module
(Slot X, Socket Y)
System AC Power
Problem (Power
Supply X)
4-16
continued
Event Type
Expansion bus error
System lockup
Power supply failure
Power supply not
redundant
System configuration
battery low
Power module failure
AC voltage problem
Action
Replace the PCI
board.
Examine the
Integrated
Management Log
(IML) to determine the
cause of the lockup,
and then refer to
Chapter 5, "Error
Recovery," for
information on problem
resolution.
Replace the power
supply.
Add a power supply or
replace the failed
power supply.
Replace the system
configuration battery.
Replace the power
module.
Correct problem with
AC power supplied to
system.
continued
HP Servers Troubleshooting Guide