HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 268

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

ADU Error Messages
Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Storage enclosure on SCSI
bus X indicated an overheated
condition.
SOLUTION: Make sure all
cooling fans are operating
properly. Also be sure the
operating environment of
storage enclosure is within
temperature specifications.
Storage enclosure on SCSI
bus X is unsupported with its
current firmware version.
SOLUTION: Upgrade the
firmware version on the
storage enclosure.
Storage enclosure on SCSI
bus X indicated that the fan
failed.
SOLUTION: Replace the fan.
D-18
Description
The external storage unit is
generating a temperature alert.
The firmware version of the
external storage unit is not
supported.
The cooling fan located in the
external storage unit has
experienced a failure.
continued
Recommended Action
1.
Be sure that all fans are
connected and operating
properly.
2.
Be sure that the operating
environment of the
storage unit is within
specifications.
3.
For better airflow, remove
any dust buildup from fans
or other areas.
4.
Check your server-
specific user
documentation for
allowable temperature
specifications and
additional tips.
5.
If none of the previous
steps solve this problem,
replace the fan.
Upgrade the firmware.
Replace the fan.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading

Table of Contents