1600 Series Post Error Messages - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages

1600 Series POST Error Messages

Table C-12: 1600 Series POST Error Messages
Error Code
1610- Temperature
violation detected. -
Waiting 5 Minutes for
System to Cool.
1610- Temperature
violation detected.
Waiting for system
to cool
1610-I/O Board
Temperature Violation
detected
1611-Fan X not
present
1611-CPU Fan failure
detected
C-38
Audible
Probable Source of
Beeps
Problem
None
The ambient system
temperature has
exceeded acceptable
levels.
2 short
The ambient system
temperature is too hot.
None
An overheating condition
has occurred on the I/O
board.
2 short
Fan is not installed or is
not seated.
None
Required fan not
spinning.
Action
Room temperature is too
high; lower the room
temperature.
Check fan in system
environment.
Turn off system and let it cool
down. Be sure that the
system fans are functional
and that the rack allows
adequate ventilation.
Also, be sure that the ambient
temperature is within the
operating parameters of the
system. Check your server-
specific user documentation
for the temperature
requirements of your server.
Reseat or install a fan in
position X.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
HP Servers Troubleshooting Guide