HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 235

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table C-13: 1700 Series POST Error Messages
Error Code
1757 - Array
Accelerator
Daughterboard
incompatible with this
model controller
1758- Drive Array -
Accelerator Size
Mismatch Between
Controllers 64MB
Array Accelerator
should be attached to
both controllers. Array
Accelerator is
temporarily disabled.
1759-Slot z Drive
Array – Redundant
Controller Error
1760-Fixed Disk X
does not support
Block Mode
1761-Fixed Disk 1
does not support
Block Mode
1762-Redundant
controller operation is
not supported in this
firmware version.
1763- Array
Accelerator
daughtercard is
detached; please
reattach.
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
4-MB array accelerator
board installed on Smart
Array 42XX Controller.
None
Redundant Smart Array
4250ES Controller pair
with incorrect array
accelerator installed.
None
Redundant controller
problem.
None
Fixed disk drive error
detected.
None
Fixed disk drive error
detected.
None
Old firmware on
controller (does not
support redundant-
controller operation).
None
Array accelerator module
is loose, missing, or
defective.
continued
Action
Replace 4-MB array
accelerator board with a
16-MB or 64-MB board.
Install 64-MB array
accelerator module on both
Smart Array 4250ES
Controllers.
Replace or reseat controllers.
May also be caused by a
defective system board.
Run the server setup utility
and correct.
Run the server setup utility
and correct.
Upgrade controller firmware
using Options ROMPaq.
Replace array accelerator
module, or reseat if connector
is not fully mated.
POST Error Messages
continued
C-55

Advertisement

Table of Contents
loading

Table of Contents