POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1764-Slot X Drive
Array – Capacity
Expansion Process is
temporarily disabled
(followed by one of
the following):
Expansion will
resume when Array
Accelerator has been
reattached.
Expansion will
resume when Array
Accelerator has been
replaced.
Expansion will
resume when Array
Accelerator RAM
allocation is
successful.
Expansion will
resume when Array
Accelerator battery
reaches full charge.
Expansion will
resume when
automatic data
recovery has been
completed.
1766-Slot X Drive
Array requires System
ROM Upgrade. Run
Systems ROMPaq
Utility.
C-56
Audible
Probable Source of
Beeps
Problem
None
The capacity expansion
process has been
temporarily disabled for
the reason that is
described onscreen.
None
System ROM upgrade is
required
continued
Action
Follow the action that is
displayed onscreen to resume
the capacity expansion
process.
Run the latest system
ROMPaq utility to upgrade the
system ROM as indicated.
Download it from the following
website:
www.compaq.com/support.