HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 224

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-12: 1600 Series POST Error Messages
Error Code
1618-AC Line is not
cord redundant
1619-Maximum
Power Usage was
exceeded
1619- Server
management board is
in the wrong slot
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
1620-Fan Not Present
C-44
Audible
Probable Source of
Beeps
Problem
None
AC line cord redundancy
is not achieved.
None
System has reached the
maximum power draw for
the current power
configuration of the
server.
None
The server management
board is not in the proper
location.
None
SCSI bus failure
detected.
None
Fans are missing or not
cabled correctly.
continued
Action
AC line cord redundancy is
not necessary for the server
to operate. If AC line cord
redundancy is wanted, plug
server into two separate
AC sources. Each AC source
should be on a different
power grid/circuit.
1.
If running on a 110-volt
AC source, switch to
220-volt.
2.
Add an extra power
supply/SPM pair.
3.
Decrease the options in
the system. Refer to the
power calculator on the
Web for power
considerations:
activeanswers.compaq.com/
aaconfigurator
Install the server
management board in the
correct slot.
Be sure that the integrated
SCSI controller has SCSI
termination connected.
For the system to function, it
needs the fans described in
the server-specific
maintenance and service
guide.
Be sure that the fans are
present and installed
correctly.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading

Table of Contents