POST Error Messages
Table C-4: 200 Series POST Error Messages
Error Code
207-Invalid Memory
Configuration –
Mismatched DIMMs
within DIMM Group X
207-Invalid Memory
Configuration –
Mismatched DIMMs
within DIMM Bank
Memory in Bank X
Not Utilized.
207-Invalid Memory
Configuration -
Mismatched DIMMs
within DIMM Bank.
Memory in Board X,
Bank X Not Utilized.
207-Invalid Memory
Configuration – Only
Registered SDRAM
DIMMs Are
Supported.
207-Invalid Memory
Configuration –
Unsupported DIMM in
Socket X
207-Invalid Memory
Configuration -
Unsupported DIMM In
DIMM Socket X
Only Registered DDR
DIMMs Are
Supported.
C-16
Audible
Probable Source of
Beeps
Problem
1 long, 1
Memory within 2-DIMM
short
Group X is not utilized.
One long,
Installed DIMMs in the
and one
same bank are of
short
different sizes.
1 long,
DIMMs within a bank are
1 short
mismatched or missing,
or memory board 1 is
missing.
1 long, 1
Memory module installed
short
incorrectly.
1 long, 1
Unregistered DIMMs or
short
insufficient DIMM timings.
1 long, 1
DIMM is of an
short
unsupported type.
continued
Action
Install correctly matched
DIMMs in Group X.
Install correctly matched
DIMMs.
Install correctly matched
DIMMs.
Check placement of memory
modules.
Install registered ECC
DIMMs.
Replace DIMMs in indicated
slots with supported type.