HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 247

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table C-13: 1700 Series POST Error Messages
Error Code
1790-Disk X
Configuration Error
1790-Disk X
Configuration Error
1791-Disk 1 Error
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will automatically
be written to drive
array.
1792-Secondary Disk
Controller Failure
1793-Drive Array –
Array Accelerator
Battery Depleted –
Data Lost.
(Error message 1794
also displays.)
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
Hard drive error or wrong
drive type detected.
None
Hard drive error or wrong
drive type detected.
None
Hard drive error or wrong
drive type detected.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
array accelerator
memory. Power was then
restored within several
days, and the data in the
array accelerator was
flushed to the drive array.
None
Part of the IDE drive
electronics has failed.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
array accelerator
memory.
Array accelerator
batteries failed. Data in
array accelerator has
been lost.
continued
Action
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid
data remaining in the array
accelerator.
Run Diagnostics and replace
failed assembly as indicated.
Power was not restored within
enough time. Perform orderly
system shutdowns to avoid
data remaining in the array
accelerator.
POST Error Messages
continued
C-67