Storage Fault Recovery Tracking; Storage Automatic Reconstruction; Network Interface Fault Recovery Tracking; Memory Fault Recovery Tracking - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Storage Fault Recovery Tracking

This feature tracks more than 12 failure-indication parameters for SCSI drives, such
as time-out, spin-up, and self-test errors. You can use these parameters to pinpoint
failed storage subsystem components and to recover from controller or hard drive
failures.

Storage Automatic Reconstruction

This feature automatically reconstructs data to an online spare drive or to a replaced
drive if a drive fails. To use the reconstruction feature, you must configure your
server for drive mirroring or data guarding. The reconstruction decreases system
downtime by allowing rapid recovery to full system operation.

Network Interface Fault Recovery Tracking

This feature tracks over 20 failure indication parameters, such as alignment errors,
lost frames, and frame copy errors, of Ethernet and IBM Token-Ring network
interfaces. Network interface fault recovery tracking decreases network downtime by
enabling diagnosis of actual network interface failures.

Memory Fault Recovery Tracking

This feature inspects the operation of the memory subsystem looking for
noncorrectable memory errors.
HP Servers Troubleshooting Guide
Error Recovery
5-19

Advertisement

Table of Contents
loading

Table of Contents