HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 270

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

ADU Error Messages
Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Swapped cables or
Configuration error detected. A
drive rearrangement was
attempted while an expand
operation was running. This is
an unsupported operation.
SOLUTION: Power down
system then move drives back
to their original location. Power
on system and wait for the
expand operation to complete
before attempting a drive
rearrangement.
Swapped cables or
Configuration error detected.
An unsupported drive
arrangement was attempted.
SOLUTION: Power down
system then move drives back
to their original location.
Swapped cables or
Configuration error detected.
The cables appear to be
interchanged.
SOLUTION: Power down
system then move the drives
or cables back to their original
location.
D-20
Description
One or more drive locations
were changed while an
expand operation was in
progress.
One or more physical drives
were moved, causing a
configuration that is not
supported.
ADU has detected a change in
the cable configuration.
One or more cables may be
connected to the incorrect bus.
-Or-
One or more drives have been
moved to new locations.
continued
Recommended Action
1.
Power down the server.
2.
Place the drives in their
original locations.
3.
Restart the server, and
then complete the expand
operation.
4.
Move the drives to their
new locations after the
expand operation is
completed.
Move all drives to their original
locations, and then refer to
your server-specific user
documentation for supported
configurations.
Refer to your server-specific
user documentation for
supported configurations and
cabling guidelines.
Restore to the original
configuration.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading

Table of Contents