POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1777-Slot X Drive
Array – ProLiant Drive
Storage Enclosure
Problem Detected
(followed by one or
more of the following):
SCSI Port Y: Cooling
Fan Malfunction
Detected
SCSI Port Y:
Overheated Condition
Detected
SCSI Port Y:
Side-Panel must be
Closed to Prevent
Overheating
SCSI Port Y:
Redundant Power
Supply Malfunction
Detected
SCSI Port Y: Wide
SCSI Transfer Failed
SCSI Port Y: Interrupt
Signal Inoperative
SCSI Port y:
Unsupported ProLiant
Storage System
Detected
1778-Drive Array
resuming Automatic
Data Recovery
process
C-60
Audible
Probable Source of
Beeps
Problem
None
Environment threshold
was violated on the drive
enclosure.
None
This message is
displayed whenever a
controller reset or power
cycle occurs while
Automatic Data Recovery
is in progress.
continued
Action
Check cooling fan operation
by placing hand over fan. Be
sure that internal plenum
cooling fan in tower servers or
storage systems is
operational. If fan is not
operating, check for
obstructions and check all
internal connections. Replace
unit side panel if removed.
If the ProLiant Storage
System power LED is amber
instead of green, this
indicates a redundant power
supply failure.
Check SCSI cables. If the
message indicates to check
SCSI cables, compare your
cabling against the diagrams
in your HP Smart Array
Controller user guide. If the
routing is correct, replace
cables on the specified port
until the POST message is
eliminated.
No action necessary.
HP Servers Troubleshooting Guide