HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 225

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table C-12: 1600 Series POST Error Messages
Error Code
1621-Error - Power
Supply required with
System Power
Module
1621-Current SCSI
bus cable
configuration is not
recommended
1622-Internal SCSI
Jumper Board Not
Installed.
1623-System Battery
is missing
1624-System Power
Module Failed
1625-Power Supply
Failed
1626-Power Supply
Reported Error Status
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
There are more SPMs
than power supplies.
None
Improper SCSI bus
cabling detected.
None
SCSI jumper board
missing or not functional.
The system has detected
that the array enabler
board is not installed.
None
Battery is missing or has
fallen out.
None
System Power Module
has failed.
None
Power supply has failed.
None
The power supply has
returned an error status.
continued
Action
Power supplies and System
Power Modules (SPMs) must
be installed in pairs and in line
with each other. Be sure that
an SPM is installed for each
power supply.
Check server-specific user
documentation for proper
SCSI bus cabling.
1.
Install the array enabler
board.
2.
Install the Integrated
Array Bypass Kit if a
separate controller is
used.
Check for the installation of
the battery located on the
sideplane board.
Replace specified System
Power Module.
Replace specified power
supply.
1.
Note the details of the
error status and act
accordingly. For
example, if an
over-temperature
condition has occurred,
check the system fans
and ventilation.
2.
If the problem persists,
replace power supply.
POST Error Messages
continued
C-45