HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 261

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Less than 75% of batteries at
sufficient voltage Battery pack
X below reference voltage
Logical drive X failed due to
cache error
Logical Drive X status = Failed
Logical Drive X status =
Interim recovery (volume
functional, but not fault
tolerant)
HP Servers Troubleshooting Guide
Description
Battery pack on the array
accelerator is below the
required voltage levels.
This logical drive failed due to
a catastrophic cache error.
This status could be issued for
several reasons:
Logical drive is configured
for No Fault Tolerance,
and one or more drives
fail.
Mirroring is enabled, and
any two mirrored drives
fail.
Data Guarding is enabled,
and two or more drives
fail.
Another configured logical
drive is in the WRONG
DRIVE REPLACED or
LOOSE CABLE
DETECTED state.
A physical drive in this logical
drive has failed. The logical
drive is operational, but the
loss of an additional drive
causes permanent data loss.
ADU Error Messages
continued
Recommended Action
Allow enough time for batteries
to recharge (36 hours). If
batteries have not recharged
after 36 hours, replace the
array accelerator board.
Replace the array accelerator
board and reconfigure using
ACU.
Check for drive failures, wrong
drive replaced, or loose cable
messages. If there was a drive
failure, replace the failed drive
or drives, and then restore the
data for this logical drive from
the tape backup. Otherwise,
follow the procedures for
correcting problems when an
incorrect drive is replaced or a
loose cable is detected.
Replace the failed drive as
soon as possible.
continued
D-11