Table 4-1: Event Messages
Event Message
System AC Power
Overload (Power
Supply X)
Operating System
Blue Screen Trap:
Cause [NT]
Kernel Panic: Cause
[UNIX]
Abnormal Program
Termination: Cause
[NetWare]
Automatic Operating
System Shutdown
Initiated Due to Fan
Failure
Automatic Operating
System Shutdown
Initiated Due to
Overheat Condition
Fatal Exception
(Number X, Cause)
HP Servers Troubleshooting Guide
continued
Event Type
Power supply overload
System lockup
Fan failure
Overheat condition
Action
Switch the voltage
from 110 V to 220 V or
add an additional
power supply (if
applicable to your
system).
If the problem is still
not resolved, remove
some of the options
installed.
Refer to the
documentation for your
operating system.
Replace fan.
Check fans. Also, be
sure that the server is
properly ventilated and
that the room is set
within the required
temperature range.
Diagnostic Tools
4-17