HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 198

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-4: 200 Series POST Error Messages
Error Code
207-Invalid Memory
Configuration, Bank X
207- Memory
Installation Error
207-Memory
Configuration
Warning – DIMM in
DIMM Socket X does
not have Primary
Width of 4 and only
supports standard
ECC.
208-Invalid Memory
Speed – Check DIMM
Installation
209-Memory
Detection Failure.
Check Memory
Installation.
209-Online Spare
Memory Configuration
- Bank A does not
match Bank C.
C-18
Audible
Probable Source of
Beeps
Problem
None
A memory bank has been
incorrectly populated.
None
Memory module installed
incorrectly or
unsupported DIMM.
1 long, 1
Installed DIMMs have a
short, or
primary width of x8.
none
1 long, 1
The speed of the memory
short
is not compatible.
1 long, 1
Unable to size memory.
short
1 long, 1
DIMM group mismatch
short
between Bank A and
Bank C.
continued
Action
Check the location of the
bank specified. This bank
number will correspond to the
bank number shown on the
memory expansion board
identification label located on
the top air baffle of the
processor/memory drawer.
Check that a bank has been
populated with four DIMMs of
the same type, size, and
speed.
Check placement of memory
modules.
Install DIMMs that have a
primary width of x4.
Check the speed of the
memory modules installed.
Then, check your server user
documentation and replace as
indicated.
Check memory module
installation. Check for
additional resources at
www.hp.com.
Check the size and speed of
the memory modules
installed. Then, check your
server user documentation
and replace as indicated.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading

Table of Contents