HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 246

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1789-Slot X Drive
Array SCSI Drive(s)
Not Responding.
Check cables or
replace the following
SCSI drives:
SCSI Port Y:
SCSI ID Z
Select F1 to continue
– drive array will
remain disabled.
Select F2 to failed
drives that are not
responding – Interim
Recovery Mode will
be enabled if
configured for fault
tolerance.
C-66
Audible
Probable Source of
Beeps
Problem
None
Drives that were working
when the system was last
used are now missing or
are not starting up.
Possible drive problem or
loose SCSI cable.
continued
Action
1.
Power down the system,
check cable connections,
and be sure that all
drives are fully seated in
their drive bays.
2.
Power cycle any external
SCSI enclosures while
the system is off.
3.
Power on the server to
see if problem still exists.
4.
If configured for fault-
tolerant operation and the
RAID level can sustain
failure of all indicated
drive(s), press the F2 key
to fail the drive(s) that are
not responding and
replace with good
drive(s) immediately.
5.
Otherwise, press the F1
key to start the system
with all logical drives on
the controller disabled.
Be sure that system is always
powered up and down
correctly.
When powering up the
system, all external
storage systems must be
turned on before server.
When powering down the
system, the server must
be powered down before
external storage systems.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading