6500-6599, Scsi Hard Drive Test Error Codes; Scsi Fixed Disk Drive Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

6500-6599, SCSI Hard Drive Test Error Codes

The 6500 series of diagnostic error codes identifies failures with SCSI hard drives,
SCSI hard drive controller boards, SCSI hard drive cabling, and system board
functions. If the system uses a drive array controller, refer to "Array Diagnostic
Utility" in Chapter 4 for more information about diagnosing problems with the drive
array.
Table B-12: SCSI Fixed Disk Drive Test Error Codes
Error
Description
Code
6500-XX
SCSI Disk ID drive types
test failed
6502-XX
SCSI Disk Unconditional
Format test failed
6505-XX
SCSI Disk Read test failed
6506-XX
SCSI Disk SA/Media test
failed
6509-XX
SCSI Disk Erase tape test
failed
6523-XX
SCSI Disk Random Read
test failed
6528-XX
Media load/unload test
failed
HP Servers Troubleshooting Guide
Recommended Action
The following steps apply to error codes 6500-XX
through 6528-XX:
1.
Run the server setup utility and check the drive
type.
2.
Replace the SCSI disk drive signal and power
cables and retest.
3.
Replace the SCSI controller and retest.
4.
Replace the SCSI disk drive and retest.
5.
Replace the system board and retest.
Test Error Codes
B-13

Advertisement

Table of Contents
loading

Table of Contents