HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 228

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1705-Locked SCSI
Bus Detected
1711-Slot z Drive
Array - RAID ADG
logical drive(s)
configured but Array
Accelerator size
<= 32 MB. This
configuration is not
recommended.
Consider migrating
logical drive(s) to
RAID 5 or upgrading
the Array Accelerator
module.
1712-Slot z Drive
Array - RAID 5 logical
drive(s) configured
with 56 drives, but
Array Accelerator size
<= 32 MB. This
configuration is not
recommended.
Consider migrating
logical drive(s) to
RAID 0 or 1, reducing
the number of drives
in the array, or
upgrading the Array
Accelerator module.
C-48
Audible
Probable Source of
Beeps
Problem
None
A SCSI controller cannot
communicate with
devices connected to a
SCSI bus.
None
Configuration not
recommended.
None
Configuration not
recommended.
continued
Action
1.
Check the SCSI cable
installation.
2.
Be sure that the SCSI
cable has proper
termination.
Migrate logical drive(s) to
RAID 5 or upgrade to a larger
array accelerator module.
Migrate logical drive(s) to
RAID 0 or 1, reduce the
number of drives in the array,
or upgrade to a larger-size
array accelerator module.
HP Servers Troubleshooting Guide