Page 158 of 430
553-3001-368
Standard 7.00
Nortel IP Phone 2007
After the third dot is tapped, the display changes to indicate the result of
calibration.
— If the calibration is successful, the telephone displays the following
report:
Data calibration is CORRECT.
Save Data calibration?
YES and NO soft keys and calibration statistics are displayed on the
screen.
Tap the YES soft key to save the calibration settings and exit to the
main display or tap the NO soft key to abandon the calibration
settings and exit to the main display.
— If the calibration is unsuccessful, the telephone displays the
following report:
Data calibration is WRONG.
Repeat calibration?
YES and NO soft keys and calibration statistics are displayed on the
screen.
Tap the YES soft key to retry the calibration. Return to step 15 on
page 165
to follow the calibration procedure or tap the NO soft key to
abandon the calibration and return to the main display.
Procedure 27
Installing an IP Phone 2007 for the first time
using DHCP
1
Configure a virtual loop on the system using LD 97.
For more information, see Software Input/Output: Administration
(553-3001-311).
2
Configure the IP Phone 2007 on the system using LD 11.
For more information, see Software Input/Output: Administration
(553-3001-311).
3
Connect the IP Phone 2007 components:
August 2005
End of Procedure