Hitachi PC-ARF Technical Catalogue page 88

Table of Contents

Advertisement

4 Individual remote controls
PC-ARF
Indi-
Items Optional Function
vidual
setting
Lock function for
F8
operation mode
×
selection
Lock function for
F9
×
temperature setting
Lock function for
FA
×
fan speed selection
Lock function
Fb
for swing louver
×
operation
Cooling lower
FC
limit for setting
×
temperature (*5)
Heating upper
Fd
limit for setting
×
temperature (*6)
FE
Not prepared
-
FF
Not prepared
-
H1
Not prepared
-
Indication of hot
H2
×
start
H3
Not prepared
-
H4
Not prepared
-
Temperature
J1
×
indication (*8)
J2
Not prepared
-
J3
Run indicator color
×
J4
Not prepared
-
J5
Not prepared
×
J6
Error sound
×
J7
Not prepared
-
72
TCGB0106 rev.0 - 12/2014
Setting
Contents
condition
00
Not available
Available (Factory
01
setting)
00
Not available
Available (Factory
01
setting)
00
Not available
Available (Factory
01
setting)
00
Not available
Available (Factory
01
setting)
00
Standard
01
Lower limit +1 ºC
02
Lower limit +2 ºC
...
...
09
Lower Limit +9 ºC
10
Lower Limit +10 ºC
00
Standard
01
Upper limit –1
C
o
02
Upper limit –2
C
o
...
...
11
Upper limit –11
C
o
12
Upper limit –12
C
o
00
Not used
(Use as 00 conditions)
01
Not used
00
01
(Use as 00 conditions)
Not used
00
01
(Use as 00 conditions)
00
Indication
01
No indication
Not used
00
01
(Use as 00 conditions)
Not used
00
01
(Use as 00 conditions)
00
Not available
01
Available
-
Not Used
00
Green
01
Red
Not used
00
01/02
(Use as 00 conditions)
Not used
00
(Use as 00 conditions)
01
00
Once
01
Sequence
Not used
00
01
(Use as 00 conditions)
Indi-
Items Optional Function
vidual
setting
J8
Eco-operation (*9)
×
J9
Not prepared
-
JA
Not prepared
-
Jb
Not prepared
-
K1
Not prepared
×
K2
Not prepared
×
K3
Not prepared
×
K4
Not prepared
-
Human sensor
K5
detection level
-
(*11)
(*1): The "02" setting may not be available according to the type of
indoor unit.
(*2):In case of RPI models, 00: standard, 01: high static pressure,
02: low static pressure
(*3): E1 to E4: Setting for the total heat exchanger and Econofresh.
(*4): In case that the set temperature is changed and kept within
the set time at "F4", the temperature is automatically changed to
"F5" and "F6". (In case that the set temperature is out of range at
"F5" and "F6", it is applied within upper and lower limit for the set
temperature.)
(*5): Applicable to fan, cooling and dry operation modes.
(*6): Applicable to heating operation mode.
(*7): Operation is stopped by pressing the " " (run/stop) switch for
3 seconds.
(*8): The sensor value at "C8" will be indicated. When the thermistor
for remote control switch is used, the average value of the thermis-
tor for remote control switch and the thermistor for indoor inlet will
be indicated.
(*9): When the unit is restarted by the remote control switch, the
temperature automatically changes to the setting temperature of
"F5" or "F6".
(*10): If function F2 is set up 01 (Sub) is displayed "--".
(*11): This function is for air panel with motion sensor. If the air
panel don't have available the motion sensor, setting condition is
displayed as "--".
N O T E
After at least 3 minutes from the power ON, change the optional
setting.
When changing "CF" setting (change of louver swing range), re-
store the power supply or allow the louver to make one complete
swing fully in the auto swing mode to apply the optional setting.
The optional settings are different according to the indoor and
outdoor unit models. Check to ensure that the unit has the op-
tional setting or not.
Record the setting conditions for each optional setting in the
"Setting" column of the table.
Setting
Contents
condition
00
Not available
01
Available
Not used
00
01
(Use as 00 conditions)
Not used
00
(Use as 00 conditions)
01
Not used
00
(Use as 00 conditions)
01
-
Not used
-
Not used
-
Not used
00~03
Not used
00
Standard
01
High
02
Low

Advertisement

Table of Contents
loading

Table of Contents