5 Centralised remote controls
PSC-A64GT
Setting Temperature
1 Select the target group at screen of "Monitor 1 (All Groups)" or "Monitor 2 (Block)" to change the setting temperature.
The pop-up of "Setting" for the selected group is displayed on the touchscreen.
Monitor 1 (All Groups)
Monitor 1 (All Groups)
F-Level
F-Level
1-A
1-B
Group1A-01
Group1A-02
Group1B-01
Group1B-02
Group1A-03
Group1A-04
Group1B-03
Group1B-04
Group1A-05
Group1A-06
Group1B-05
Group1B-06
Group1A-07
Group1A-08
Group1B-07
Group1B-08
Group1A-09
Group1A-10
Group1B-09
Group1B-10
Group1A-11
Group1A-12
Group1B-11
Group1B-12
Group1A-13
Group1A-14
Group1B-13
Group1A-15
Group1A-16
Menu
2 By tapping " ", the temperature is increased by 1 ºC. (Max. 30 ºC). By tapping " ", the temperature is decreased by
1 ºC.
At Cooling, Dry and Fan operation: Min. 19 ºC
At Heating operation: Min. 17 ºC
3 Tap "Close" to return to the screen of "Monitor 1 (All Groups)" or "Monitor 2 (Block)".
N O T E
In the case of "Run/Stop Only" mode, setting change is available by only "All Groups Setting" or "Setting by Block" button. (Setting
change for each group is NOT available).
The figure above shows an example of the setting temperature for the standard unit. The temperature setting range may be different
depending on the connected indoor units.
248
TCGB0106 rev.0 - 12/2014
25/01/2010 (Mon) 10:20
F-Level
Annex
2
Buffet 1
Buffet 1
Group2-01
Group2-02
North Area
South Area
Buffet 1
Buffet 1
Group2-03
Group2-04
East Area
West Area
Buffet 2
Buffet 2
Group2-05
Group2-06
North Area
South Area
Buffet 2
Buffet 2
Group2-07
Group2-08
East Area
West Area
Meeting
Meeting
Group2-09
Group2-10
Room A
Room B
Meeting
Meeting
Group2-11
Room C
Room D
Meeting
Kiosk
Room E
All Groups
All Groups
All Groups
Setting
Run
Stop
(1)
F-Level 1-A
Setting
Group1A-02
Operation
Setting
RUN/STOP OPE. MODE FAN SPEED LOUVER
RUN
DRY
STOP
Monitor 2 (Block)
Monitor 2 (Block)
F-Level
F-Level
All Groups
1-A
26
Group1A-01
Group1A-02
DRY LOW
DRY
LOW
AUTO
24
Group1A-05
Group1A-06
DRY LOW
DRY
LOW
AUTO
20
Group1A-09
Group1A-10
DRY LOW
DRY
LOW
22
Group1A-13
Group1A-14
DRY LOW
DRY
LOW
Menu
RCS Operation
Prohibited
SET TEMP.
26
LOW
AUTO
Close
(2)
25/01/2010 (Mon) 10:20
F-Level
Annex
1-B
2
26
20
Group1A-03
Group1A-04
DRY
DRY
LOW
LOW
AUTO
24
26
Group1A-07
Group1A-08
DRY
LOW
DRY
LOW
20
26
Group1A-11
Group1A-12
DRY
DRY
LOW
LOW
20
19
Group1A-15
Group1A-16
DRY
DRY
LOW
LOW
Setting by
Run by
Block
Block
(1)
(3)
25
26
23
AUTO
22
Stop by
Block