4 Individual remote controls
PC-ART
3 Select the temperature change using the TEMP buttons  . At this point, if the RESET
button is pressed, the temperature change will not be set and "- -" will be displayed.
4 By pressing the TIMER button, SET and SCHEDULE are turned off and the system
switches to operation mode.
N O T E
Carrying out this operation will change the temperature setting indicator.
The increase or decrease of the set temperature during the scheduled time (±3 °C or ±5 °C) will vary
depending on the operation mode.
If operating in "ventilation", "cooling" or "dehumidifying" mode, the temperature variation is + .
If operating in "heating" mode, the temperature variation is - .

Automatic heating operation (freeze protection)
Activation
In operation mode, press the MODE button for at least 3 seconds. Automatic heating operation is ac-
tivated and ON will appear to the right of the current time. ON will flash continuously during automatic
heating operation.
Cancellation
During automatic heating operation, press the MODE button for at least 3 seconds to change to the
operation mode.
The automatic heating operation is switched off and the ON indication to the right of the current time will
disappear.
N O T E
If the room temperature drops below a certain level*, the heating will switch on automatically. In this
case, when the room reaches the temperature setting, the system will switch off.
* The user may select (5/10/15 °C) through an optional setting (see Optional function list, option FE).

Operating lock procedure
To avoid any incorrect use of the buttons, they can be locked (see below).
Activation
In operation mode, press the SELECT ▲ ▼ buttons simultaneously for at least 3 seconds. The opera-
tion lock will be activated and OPER.LOCK will be displayed. If a button is pressed during this time,
OPER. LOCK will flash.
Cancellation
While system operation is locked, press the SELECT ▲ ▼ buttons simultaneously for at least 3 sec-
onds to return to operation mode. The operation lock will be cancelled and OPER.LOCK goes off.
N O T E
The button to be locked can be selected in "change operation mode", "temperature setting", "air
flow" and "automatic louver" through an optional setting (F8~Fb) indicated in Optional functions list.
This setting can be changed from a second remote control.
127
TCGB0106 rev.0 - 12/2014
1234S
SET
:
SCHEDULE
ON
:
OFF
S
Mon
NEXT SCHEDULE
:
:
OFF
4
Mon
NEXT SCHEDULE
:
ON
:
OFF
Mon
NEXT SCHEDULE
:
:
OFF
Mon
NEXT SCHEDULE
:
:
OFF
OPER.LOCK
Mon
NEXT SCHEDULE
:
:
OFF

Advertisement

Table of Contents
loading

Table of Contents