Hitachi PC-ARF Technical Catalogue page 263

Table of Contents

Advertisement

5 Centralised remote controls
PSC-A64GT
Swing Louver Direction
1 Select the target group at screen of "Monitor 1 (All Groups)" or "Monitor 2 (Block)" to change the swing louver direc-
tion. The pop-up of "Setting" for the selected group is displayed on the touchscreen.
Monitor 1 (All Groups)
Monitor 1 (All Groups)
F-Level
F-Level
1-A
1-B
Group1A-01
Group1A-02
Group1B-01
Group1B-02
Group1A-03
Group1A-04
Group1B-03
Group1B-04
Group1A-05
Group1A-06
Group1B-05
Group1B-06
Group1A-07
Group1A-08
Group1B-07
Group1B-08
Group1A-09
Group1A-10
Group1B-09
Group1B-10
Group1A-11
Group1A-12
Group1B-11
Group1B-12
Group1A-13
Group1A-14
Group1B-13
Group1A-15
Group1A-16
Menu
2 By tapping " " or " " of the "LOUVER", the swing louver direction will be changed alternately as follows.
: Auto swing operation will be started.
AUTO
3 Tap "Close" to return to the screen of "Monitor 1 (All Groups)" or "Monitor 2 (Block)".
N O T E
In the case of "Run/Stop Only" mode, setting change is available by only "All Groups Setting" or "Setting by Block" button. (Setting
change for each group is NOT available).
This function (swing louver direction) may not be set depending on the unit model.
Louver position on LCD and the actual louver position do not always match during the auto swing operation.
The louver may not stop immediately after the switch is pressed.
247
TCGB0106 rev.0 - 12/2014
25/01/2010 (Mon) 10:20
F-Level
Annex
2
Buffet 1
Buffet 1
Group2-01
Group2-02
North Area
South Area
Buffet 1
Buffet 1
Group2-03
Group2-04
East Area
West Area
Buffet 2
Buffet 2
Group2-05
Group2-06
North Area
South Area
Buffet 2
Buffet 2
Group2-07
Group2-08
East Area
West Area
Meeting
Meeting
Group2-09
Group2-10
Room A
Room B
Meeting
Meeting
Group2-11
Room C
Room D
Meeting
Kiosk
Room E
All Groups
All Groups
All Groups
Setting
Run
Stop
(1)
LCD
indication
AUTO
Angle range
COOL
DRY
Angle range
HEAT
FAN
F-Level 1-A
Setting
Group1A-02
Operation
Setting
RUN/STOP OPE. MODE FAN SPEED LOUVER
RUN
DRY
LOW
STOP
Monitor 2 (Block)
Monitor 2 (Block)
F-Level
F-Level
All Groups
1-A
1-B
26
26
Group1A-01
Group1A-02
DRY LOW
DRY
LOW
AUTO
AUTO
24
24
Group1A-05
Group1A-06
DRY LOW
DRY
LOW
AUTO
20
20
Group1A-09
Group1A-10
DRY LOW
DRY
LOW
22
20
Group1A-13
Group1A-14
DRY LOW
DRY
LOW
Menu
RCS Operation
Prohibited
SET TEMP.
26
AUTO
Close
(2)
25/01/2010 (Mon) 10:20
F-Level
Annex
2
20
25
Group1A-03
Group1A-04
DRY
LOW
DRY
LOW
26
26
Group1A-07
Group1A-08
DRY
LOW
DRY
LOW
26
23
Group1A-11
Group1A-12
DRY
DRY
LOW
LOW
AUTO
19
22
Group1A-15
Group1A-16
DRY
DRY
LOW
LOW
Setting by
Run by
Stop by
Block
Block
Block
(1)
(3)
5