Hitachi PC-ARF Technical Catalogue page 290

Table of Contents

Advertisement

5 Centralised remote controls
PSC-A64GT
1 Select "Optional Function Setting" on the "Service Menu" screen when the air conditioners are not in operation.
N O T E
This function cannot be selected when the air conditioner is operating.
2 Select the target groups or block for "Optional Function Setting" by tapping "All Groups", "Block" or "Group".
Select "All Groups" for the optional function setting when the following item settings are changed.
Operation mode
Display of Accumulated Operation Time
(1)
Service Menu
Optional Function
Group Register
Setting
Exception
Demand Function
External Input
Setting
Checking
Restore Setting
Connection
Alarm History
3 Select "Enable" or "Disable" for the each function.
The button colour of selected function is changed to yellow
with orange rim.
Proceed to select the optional function setting depending on
the setting afterwards.
Set the optional function of other group.
Exit the optional function setting.
4 Tap "Back" to return to the screen of "Optional Function
Setting". Repeat (2) and (3) to set "Optional Function Set-
ting".
5 Tap "Done" to finish this setting. The screen is returned to
"Service Menu".
274
TCGB0106 rev.0 - 12/2014
25/01/2010 (Mon) 10:20
Exception Setting
External
of Run/Stop
Input/Output Setting
Operation
Contact Info.
Button Setting
Register
Back
(4)
(5)
Optional Function Setting
F-Level
F-Level
1-A
1-B
Group1A-01
Group1A-02
Group1B-01
Group1B-02
Group1A-03
Group1A-04
Group1B-03
Group1B-04
Group1A-05
Group1A-06
Group1B-05
Group1B-06
Group1A-07
Group1A-08
Group1B-07
Group1B-08
Group1A-09
Group1A-10
Group1B-09
Group1B-10
Group1A-11
Group1A-12
Group1B-11
Group1B-12
Group1A-13
Group1A-14
Group1B-13
Group1A-15
Group1A-16
Optional Function
F-Level 1-B
Group1B-03
Setting
Fixing
Enable
Disable
Control Mode
Operation Mode
Fixing
RCS Operation is
Temperature
Prohibited to set
Enable
Disable
Setting
OFF time
Display of
Enable
Disable
Accumulated
Cooling Only
Operation Time
Enable
Disable
Auto
Fixing Fan Speed
Enable
Disable
25/01/2010 (Mon) 10:20
F-Level
Annex
2
Buffet 1
Buffet 1
Group2-01
Group2-02
North Area
South Area
Buffet 1
Buffet 1
Group2-03
Group2-04
East Area
West Area
Buffet 2
Buffet 2
Group2-05
Group2-06
North Area
South Area
Buffet 2
Buffet 2
Group2-07
Group2-08
East Area
West Area
Meeting
Meeting
Group2-09
Group2-10
Room A
Room B
Meeting
Meeting
Group2-11
Room C
Room D
Meeting
Kiosk
Room E
All Groups
Back
(2)
25/01/2010 (Mon) 10:20
Run/Stop
Normal
Only
Enable
Disable
Enable
Disable
(3)
Done
Back
(4)
(5)

Advertisement

Table of Contents
loading

Table of Contents