Network performance
Complete the following steps until the problem is solved:
1. Isolate which network is operating slowly (such as storage, data, and management). You might find it
helpful to use ping tools or operating-system tools such as task manager or resource manager.
2. Check for traffic congestion on the network.
3. Update the NIC device driver, or the storage device controller device driver.
4. Use the traffic-diagnostic tools that are provided by the IO-module manufacturer.
Operating system performance
Complete the following steps until the problem is solved:
1. If you have recently made changes to the compute node (for example updated device drivers or installed
software applications) remove the changes.
2. Check for any networking issues.
3. Check the operating system logs for performance related errors.
4. Check for events related to high temperatures and power issues as the compute node might be throttled
to help with cooling. If it is throttled, reduce the workload on the compute node to help improve
performance.
5. Check for events related to disabled DIMMs. If you do not have enough memory for the application
workload, your operating system will have poor performance.
6. Ensure that the workload is not too high for the configuration.

Power on and power off problems

Use this information to resolve issues when powering on or powering off the server.
"The power button does not work (server does not start)" on page 399
"Server does not power on" on page 400
The power button does not work (server does not start)
Note: The power button will not function until approximately 1 to 3 minutes after the server has been
connected to power source to allow time for BMC to initialize.
Complete the following steps until the problem is resolved:
1. Make sure that the power buttons on the server are working correctly:
a. If the power button on the rear operator panel does not work:
1) If the power button on the front operator panel does not work as well, go to
2) If the power button on the front operator panel is working correctly, reseat the rear operator
panel and the cable that connects front and rear operator panels; then, reseat the server power
cords.
3) If the problem remains, go to
b. If the power button on the front operator panel does not work, or the power button on the rear
operator panel does not work after completing Step a:
1) If the power button on the rear operator panel is working correctly, reseat the front operator
panel; then, reseat the server power cords.
2) Reseat the cable that connects the front operator panel to the system board; then, reseat the
server power cords.
b. on page
399.
b. on page
.
Chapter 8
Problem determination
399.
399