Shock and vibration specifications
The following information is a summary of the shock and vibration specifications of the server. Depending on
the model, some features might not be available, or some specifications might not apply.
Table 1. Shock and vibration specifications
Mounting type of
Shock
ThinkEdge SE360
(when the server is in
V2
operation)
Half-sine wave, 15G
Desktop mount
11ms
(standing alone)
Half-sine wave, 15G
Rack mount (in
3ms
2U2N enclosure)
Half-sine wave, 15G
DIN-rail mount
11ms
Wall mount
• Half-sine wave,
• Half-sine wave,
Not applicable
Ceiling mount
Particulate contamination
Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in
combination with other environmental factors such as humidity or temperature might pose a risk to the
device that is described in this document.
Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases
include damage that might cause the device to malfunction or cease functioning altogether. This
specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits
must not be viewed or used as definitive limits, because numerous other factors, such as temperature or
moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous
contaminant transfer. In the absence of specific limits that are set forth in this document, you must
implement practices that maintain particulate and gas levels that are consistent with the protection of human
health and safety. If Lenovo determines that the levels of particulates or gases in your environment have
caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts
on implementation of appropriate remedial measures to mitigate such environmental contamination.
Implementation of such remedial measures is a customer responsibility.
Shock
(when the server is
not in operation,
such as in shipping)
Trapezoidal wave,
50G 167 inch/sec
Free-fall drop height:
100mm
Equivalent shock:
152 inch/sec, 2-3 ms
Not applicable
Not applicable
40G 6ms
30G 11ms
Not applicable
Vibration
Vibration
(when the server is in
(when the server is
operation)
not in operation,
such as in shipping)
5-100 Hz, 0.15 Grms,
2-200 Hz, 1.04 Grms,
30 mins
15 mins
5-500 Hz, 0.21 Grms,
2-200 Hz, 0.8 Grms,
15mins
15 mins
Not applicable
5-100 Hz, 0.15 Grms,
30 mins
Not applicable
• 1.91 Grms, 10-
500z, 30 mins
• 1.04 Grms, 10-
500z, 1 hr
Not applicable
• 1.91 Grms, 10-
500z, 30 mins
• 1.04 Grms, 10-
500z, 1 hr
Chapter 1
.
Introduction
13