Power problems

Table 25. Power problems and actions
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
• Go to the IBM support website at
tips, and new device drivers or to submit a request for information.
Symptom
The power-control button does
not work, and the reset button
does not work (the server does
not start).
Note: The power-control
button will not function until
approximately 5 to 10 seconds
after the server has been
connected to power.
The server does not turn off.
http://www.lenovo.com/support
Action
1. Make sure that the power-control button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained technician only) Reseat the operator information panel cable, and
then repeat steps 1a and 1b.
• (Trained technician only) If the server starts, reseat the operator
information panel. If the problem remains, replace the operator
information panel.
• If the server does not start, bypass the power-control button by using the
force power-on jumper (see
page
27). If the server starts, reseat the operator information panel. If the
problem remains, replace the operator information panel.
2. Make sure that :
a. The power cords are correctly connected to the server and to a working
electrical outlet.
b. The type of memory that is installed is correct.
c. The DIMM is fully seated.
d. The LEDs on the power supply do not indicate a problem.
e. The microprocessors are installed in the correct sequence.
3. Reseat the following components:
a. DIMMs
b. (Trained technician only) Power switch connector
c. (Trained technician only) Power backplane
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. DIMMs
b. (Trained technician only) Power switch connector
c. (Trained technician only) Power backplane
d. (Trained technician only) System board
5. If you just installed an optional device, remove it, and restart the server. If the
server now starts, you might have installed more devices than the power supply
supports.
6. See
"Solving undetermined problems" on page
1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
to check for technical information, hints,
"System-board switches and jumpers" on
130.
.
Chapter 4
Troubleshooting
123