YASKAWA G7 Series Technical Manual page 178

Table of Contents

Advertisement

Reference Detection: L4
User parameters for the reference detection function are shown in the following table.
Parameter
Number
L4-01
L4-02
L4-03
L4-04
L4-05
-66
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Display
Speed
These parameters configure the
Agreement
multi-function output (H2-oo)
Detection
settings "Fref/Fout Agree 1",
Level
"Fref/Set Agree 1", "Frequency
Detection 1," and "Frequency
detection 2". Parameter L4-01
sets the level while parameter
Spd Agree
L4-02 sets the hysteresis for the
Level
Speed Detection Output
Function.
Speed
These parameters configure the
Agreement
multi-function output (H2-oo)
Detection
settings "Fref/Fout Agree 1",
Width
"Fref/Set Agree 1", "Frequency
Detection 1," and "Frequency
detection 2". Parameter L4-01
sets the level while parameter
Spd Agree
L4-02 sets the hysteresis for the
Width
Speed Detection Output
Function.
Speed
These parameters configure the
Agreement
Multi-Function Output (H2-oo)
Detection
settings "Fref/Fout Agree 2",
Level (+/-)
"Fref/Set Agree 2", "Frequency
Detection 3," or "Frequency
Detection 4". Parameter L4-03
sets the level while parameter
Spd Agree
L4-04 sets the hysteresis for the
Lvl+-
Speed Detection Output
Function.
Speed
These parameters configure the
Agreement
Multi-Function Output (H2-oo)
Detection
settings "Fref/Fout Agree 2",
Width (+/-)
"Fref/Set Agree 2", "Frequency
Detection 3," or "Frequency
Detection 4". Parameter L4-03
sets the level while parameter
Spd Agree
L4-04 sets the hysteresis for the
Wdth+-
Speed Detection Output
Function.
Frequency
Determines how the Drive will
Reference
react when the frequency
Loss
reference is lost. The frequency
Detection
reference is considered lost
Selection
when reference drops 90% or
more of its current value for
400ms.
0: Stop - Drive will stop.
1: Run at L4-06 PrevRef -
Ref Loss
Drive will run at the
Sel
percentage set in L4-06 of the
frequency reference level at
the time frequency reference
was lost.
Control Methods
Change
Setting
Factory
V/f
during
Range
Setting
V/f
with
Operation
PG
0.0
to
0.0Hz
No
A
400.0
0.0
to
2.0Hz
No
A
20.0
-400.0
to
0.0Hz
No
A
+400.0
0.0
to
2.0Hz
No
A
20.0
0 to 1
0
No
A
Open
Open
MODBUS
Loop
Flux
Loop
Register
Vector
Vector
Vector
1
2
A
A
A
A
499H
A
A
A
A
49AH
A
A
A
A
49BH
A
A
A
A
49CH
A
A
A
A
49DH