YASKAWA G7 Series Technical Manual page 197

Table of Contents

Advertisement

Name
Parameter
Description
Number
Display
Motor Base
Sets the base speed of the
Speed
T1-07
motor in revolutions per
minute (RPM).
Rated Speed
Number of
Sets the number of pulses per
PG Pulses
revolution (PPR) for the
T1-08
encoder (pulse generator)
PG Pulses/
being used without any
Rev
multiplication factor.
* 1. Set T1-02 and T1-04 when 2 is set for T1-01. Only set value 2 is possible for V/f control or V/f control with PG.
* 2. Setting value for 208-240Vac. Double the value when working with 380-480Vac drives.
* 3. Factory settings will vary based on drive capacity (values given here are for 208-240Vac, 0.4kW).
* 4. Setting range is 10% to 200% of the drive's rated output current (values given here are for 208-240Vac, 0.4kW).
* 5. The upper setting limit will be 150.0Hz when C6-01 is set to 0.
* 6. Use this type of auto-tuning only if having problems with precision when tuning.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Control Methods
Change
Setting
Factory
V/f
during
Range
Setting
V/f
with
Operation
PG
0
1750
to
No
No
No
−1
min
24000
0
to
600
No
No
Yes
60000
User Parameter Tables
Open
Open
MODBUS
Loop
Flux
Loop
Register
Vector
Vector
Vector
1
2
Yes
Yes
Yes
707H
No
Yes
No
708H
85
5-

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents