YASKAWA G7 Series Technical Manual page 354

Table of Contents

Advertisement

Related Parameters
Parameter
Number
DC Injection
Braking Start
Frequency
b2-01
DCInj Start
Freq
Zero Servo
Gain
b9-01
Zero Servo
Gain
Zero Servo
Completion
Width
b9-02
Zero Servo
Count
-136
6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Display
Sets the frequency at which DC
injection braking starts when
ramp to stop (b1-03 = 0) is
selected. If b2-01< E1-09, DC
Injection braking starts at E1-09.
Note: Zero Speed restrictions are
active in Flux Vector Mode.
Sets the position loop gain for
Zero Servo command. This
function is effective when
multi-function input "zero servo
command" is set.
Sets number of pulses used for the
multi-function output of "zero
servo completion".
Change
Setting
Factory
during
Range
Setting
Operation
V/f
0.0
to
0.5Hz
No
A
10.0
0 to 100
5
No
No
0
to
10
No
No
16383
Control Methods
Open
Open
V/f
Loop
Flux
Loop
with
Vector
Vector
Vector
PG
1
2
A
A
A
A
No
No
A
No
No
No
A
No