YASKAWA G7 Series Technical Manual page 376

Table of Contents

Advertisement

F5-09 Set to 0
Set Value
0: 8 separate
outputs
F5-09 Set to 1
Set Value
1: Binary code
output
The following table shows the code outputs.
Bits 3, 2, 1,
and 0
0000
0001
0010
0011
0100
0101
0110
0111
F5-09 Set to 2
Output depends on the settings in F5-01 to F5-08.
-158
6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Terminal
Number
TD5-TD11
Overcurrent (SC, OC, GF)
TD6-TD11
Overvoltage (OV)
TD7-TD11
Drive overload (OL2)
TD8-TD11
Fuse blown (PUF)
TD9-TD11
Overspeed (OS)
TD10-TD11
Drive overheated (OH1) or motor overload (OL1)
TD1-TD2
Zero speed detected
TD3-TD4
Speed agreement
Terminal
Number
TD5-TD11
bit 0
TD6-TD11
bit 1
TD7-TD11
bit 2
TD8-TD11
bit 3
TD9-TD11
Zero speed detected
TD10-TD11
Speed agreement
TD1-TD2
Operating
TD3-TD4
Minor fault
Output Details
No error
Overcurrent (SC, OC, GF)
Overvoltage (OV)
Drive overload (OL2)
Drive overheated (OH, OH1)
Overspeed (OS)
Fuse blown (PUF)
Dynamic braking resistor (RH)
Injection brake transistor error (RR)
Output Details
Output Details
Encoded output
(Refer to table below)
Bits 3, 2, 1,
Output Details
and 0
1000
External fault (EFxx)
1001
Controller error (CPFxx)
1010
Motor overload (OL1)
1011
Not used
1100
Power loss (UV1, UV2, or UV3)
1101
Speed deviation (DEV)
1110
PG open circuit (PGO)
1111
Not used