YASKAWA G7 Series Technical Manual page 423

Table of Contents

Advertisement

Type
Name
PG-A2
Built-in
PG
PG-B2
(con-
Speed
nect to
Con-
con-
trol
nector)
Cards
PG-D2
PG-X2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 9.5 Option Cards (Continued)
Code
Number
Used for V/f with PG control. Speed feedback is performed
using the PG attached to the motor to compensate for speed
fluctuations caused by slipping.
73600-
• A-phase pulse (single pulse) input (voltage, complemen-
A012X
tary, open-collector input)
• Maximum input frequency: 32767 Hz
• Pulse monitor output: +12 V, 20 mA
(PG power supply output: +12 V, 200 mA max.)
• Used for V/f control.
• A-, B-phase input (complimentary input)
73600-
• Maximum input frequency: 32767 Hz
A013X
• Pulse monitor output: Open-collector
(PG power supply output: +12 V, 200 mA max.)
• Differential input.
• A-phase pulse (differential pulse) input, for V/f control
73600-
• Maximum input frequency: 300 kHz
A014X
• Input: Conforms to RS-422
• Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
• A-, B-, Z-phase pulse (differential pulse) input
• Maximum input frequency: 300 kHz
73600-
• Input: Conforms to RS-422
A015X
• Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
Specifications of Options and Peripheral Devices
Function
Document
Number
-
-
-
-
7
9-

Advertisement

Table of Contents

Troubleshooting

loading