Table 10 V/f Pattern Default Settings for Drive Capacity 2.2~45kW for 240V Class (Continued)
Parameter
Name
No.
E1-03
V/f Pattern Selection
E1-04
Max. Output Frequency
E1-05
Max. Output Voltage
E1-06
Base Frequency
E1-07
Mid. Output Frequency A
E1-08
Mid. Output Voltage A
E1-09
Min. Output Frequency
E1-10
Mid. Output Voltage
E1-11
Mid Output Frequency B
E1-12
Mid Output Voltage B
E1-13
Base Voltage
For 480V class units, the value is twice that of 240V class units.
Table 11 V/f Pattern Default Settings for Drive Capacity 55~300kW for 240V Class
Parameter
Name
No.
E1-03
V/f Pattern Selection
Max. Output
E1-04
Frequency
E1-05
Max. Output Voltage
Max. Voltage
E1-06
Frequency
Mid. Output
E1-07
Frequency A
Mid. Output
E1-08
Voltage A
Min. Output
E1-09
Frequency
Mid. Output
E1-10
Voltage
E1-11
Mid Output Frequency B
E1-12
Mid Output Voltage B
E1-13
Base Voltage
For 480V class units, the value is twice that of 240V class units.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Unit
8
9
A
Hz
50.0
50.0
60.0
V
240.0
240.0
240.0
Hz
50.0
50.0
60.0
V
2.5
2.5
3.0
V
20.7
26.4
20.7
Hz
1.3
1.3
1.5
V
10.3
12.6
10.3
Hz
0
0
V
0
0
V
0
0
Unit
0
1
Hz
50.0
60.0
60.0
V
240.0
240.0
240.0
Hz
50.0
60.0
50.0
V
2.5
3.0
3.0
V
13.8
13.8
13.8
Hz
1.3
1.5
1.5
V
6.9
6.9
6.9
Hz
0
0
V
0
0
V
0
0
Individual Functions
Factory Setting
B
C
D
60.0
90.0
120.0
240.0
240.0
240.0
60.0
60.0
60.0
3.0
3.0
3.0
26.4
16.1
16.1
1.5
1.5
1.5
14.9
8.0
8.0
0
0
0
0
0
0
0
0
0
0
0
0
Factory Setting
2
3
4
5
72.0
50.0
50.0
240.0
240.0
240.0
60.0
50.0
50.0
3.0
25.0
25.0
13.8
40.2
57.5
1.5
1.3
1.3
6.9
5.7
6.9
0
0
0
0
0
0
0
0
0
0
0
0
E
F
180.0
60.0
240.0
240.0
60.0
60.0
3.0
3.0
16.1
16.1
1.5
1.5
8.0
8.0
0
0
0
0
0
0
6
7
60.0
60.0
240.0
240.0
60.0
60.0
30.0
30.0
40.2
57.5
1.5
1.5
5.7
6.9
0
0
0
0
0
0