Option Parameters: F

The following settings are made with the option parameters (F parameters): Settings for Option Cards.
PG Option Setup: F1
User parameters for the PG Speed Control Card are shown in the following table.
Name
Parameter
Number
Display
PG Parameter Sets the number of pulses per
F1-01
revolution (PPM) of the
PG Pulses/
encoder (pulse generator).
Rev
Operation
Sets stopping method when a
Selection at
PG open circuit fault (PGO)
PG Open
occurs. See parameter F1-14.
Circuit
0: Ramp to stop - Decelerate
(PGO)
to stop using the active
deceleration time.
F1-02
1: Coast to stop
2: Fast - Stop - Decelerate to
PG Fdbk
stop using the deceleration
Loss Sel
time in C1-09.
3: Alarm Only - Drive
continues operation.
Operation
Sets the stopping method
Selection at
when an overspeed (OS)
Overspeed
fault occurs. See F1-08 and
(OS)
F1-09.
0: Ramp to stop - Decelerate
to stop using the active
F1-03
deceleration time.
1: Coast to stop
PG
2: Fast - Stop - Decelerate to
Overspeed
stop using the deceleration
Sel
time in C1-09.
3: Alarm Only - Drive
continues operation.
Operation
Sets the stopping method
Selection at
when a speed deviation
Deviation
(DEV) fault occurs.
See F1-10 and F1-11.
0: Ramp to stop - Decelerate
to stop using the active
F1-04
deceleration time.
1: Coast to stop
PG
2: Fast - Stop - Decelerate to
Deviation Sel
stop using the deceleration
time in C1-09.
3: Alarm Only - Drive
continues operation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting
Factory
Description
Range
Setting
0
to
1024
60000
0 to 3
0 to 3
0 to 3
User Parameter Tables
Control Methods
Change
Open
V/f
during
Loop
V/f
with
Operation
Vector
PG
1
No
No
Q
No
1
No
No
A
No
1
No
No
A
No
3
No
No
A
No
Open
MODBUS
Flux
Loop
Register
Vector
Vector
2
Q
No
380H
A
No
381H
A
A
382H
A
A
383H
41