Comparing Drive Parameters and Digital Operator Parameter Set Values (VERIFY)
To compare Drive parameters and Digital Operator parameter set values, make the settings using the following
method.
Step
Digital Operator Display
No.
-ADV-
** Main Menu **
1
Programming
-ADV-
Initialization
2
A1
- 00=1
Select Language
-ADV-
COPY Function
3
o3
- 01=0
Copy Funtion Sel
-ADV-
Copy Funtion Sel
4
o3-01=
0
*0*
COPY SELECT
-ADV-
Copy Funtion Sel
5
o3-01=
3
*0*
-ADV-
VERIFY
6
DATA VERIFYING
-ADV-
VERIFY
7
VERIFY COMPLETE
-ADV-
Copy Funtion Sel
8
o3 - 01=0
*0*
COPY SELECT
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 6.3 VERIFY Function Procedure
Press the MENU Key. and select advanced programming mode.
Press the DATA/ENTER Key, and select the parameter monitor display.
Display o3-01 (Copy Function Selection) using the Increment Key and Decrement
Key.
Press the DATA/ENTER Key, and select the function setting display.
Change the set value to 3 using the Increment Key.
Set the changed data using the DATA/ENTER Key. The VERIFY function will
start.
If the VERIFY function ends normally, End is displayed on the Digital Operator.