YASKAWA G7 Series Technical Manual page 212

Table of Contents

Advertisement

208-240Vac Drives of 55 to 110 kW and 380-480Vac Drives of 55 to 300 kW
Parameter
No.
V/F Pattern
E1-03
Selection
Max. Output
E1-04
Frequency
Max. Output
E1-05
Voltage
Max. Voltage
E1-06
Frequency
Mid. Output
E1-07
Frequency
Mid. Output
E1-08
Voltage
Min. Output
E1-09
Frequency
Min. Output
E1-10
Voltage
1.
The setting shown are for 208-240Vac Drives. The values will double for 380-480Vac Drives.
2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)
Table 5.5 V/F Pattern for Drive Capacity G7U2055 and higher for 208-240V Class (continued)
Parameter
No.
V/F Pattern
E1-03
Selection
Max. Output
E1-04
Frequency
Max. Output
E1-05
Voltage
E1-06
Base Frequency
Mid. Output
E1-07
Frequency
Mid. Output
E1-08
Voltage
Min. Output
E1-09
Frequency
Min. Output
E1-10
Voltage
1.
The setting shown are for 208-240Vac Drives. The values will double for 380-480Vac Drives.
2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)
-100
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 5.5 V/F Pattern for Drive Capacity G7U2055 and higher for 208-240V Class
Name
Unit
0
Hz
50.0
V
230.0
Hz
50.0
V
2.5
V
13.8
Hz
1.3
V
6.9
Name
Unit
8
Hz
50.0
V
230.0
Hz
50.0
V
2.5
V
17.2
Hz
1.3
V
8.0
Factory Setting
1
2
3
60.0
60.0
72.0
230.0
230.0
230.0
60.0
50.0
60.0
3.0
3.0
3.0
13.8
13.8
13.8
1.5
1.5
1.5
6.9
6.9
6.9
.
Factory Setting
9
A
B
50.0
60.0
60.0
90.0
230.0
230.0
230.0
230.0
50.0
60.0
60.0
60.0
2.5
3.0
3.0
3.0
23.0
17.2
23.0
13.8
1.3
1.5
1.5
1.5
10.3
8.0
12.6
6.9
4
5
6
50.0
50.0
60.0
230.0
230.0
230.0
50.0
50.0
60.0
25.0
25.0
30.0
40.2
57.5
40.2
1.3
1.3
1.5
5.7
6.9
5.7
C
D
E
F & FF
120.0
180.0
230.0
230.0
60.0
60.0
3.0
3.0
13.8
13.8
1.5
1.5
6.9
6.9
7
60.0
230.0
60.0
30.0
57.5
1.5
6.9
60.0
230.0
60.0
3.0
13.8
1.5
6.9

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents