Multi-function Analog Outputs: H4
User parameters for multi-function analog outputs are shown in the following table.
Parameter
Number
Terminal
FM
Monitor
Selection
H4-01
Terminal
FM Sel
Terminal
FM Gain
Setting
H4-02
Terminal
FM Gain
Terminal
FM Bias
Setting
H4-03
Terminal
FM Bias
Terminal
AM
Monitor
H4-04
Selection
Terminal
AM Sel
Terminal
AM Gain
Setting
H4-05
Terminal
AM Gain
Terminal
AM Bias
Setting
H4-06
Terminal
AM Bias
Terminal
FM Signal
Level
H4-07
Selection
AO Level
Select1
Terminal
AM Signal
Level
H4-08
Selection
AO Level
Select 2
* In order to adjust the meter, 100% of the appropriate output is multiplied for the gain setting, the bias amount is added and then output.
See H4-02 when stopped in Quick, Advanced, or Verify mode. If 03 appears on the setting screen, then terminal FM is used.
See H4-04 when stopped in Quick, Advanced, or Verify mode. If 06 appears on the setting screen, then terminal AM is used.
-58
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Display
Selects the monitor output
(U1-xx) function for terminals
FM and FC. Refer to "U1-xx"
monitors for available settings.
Unavailable settings:
4, 10, 11, 12, 13, 14, 25, 28, 29,
30, 31, 34, 35, 39, 40, 41, 42,
47, 49, 50
Sets terminal FM output level
when selected monitor is at
100%.*
Sets terminal FM output level
when selected monitor is at
0%.*
Selects which monitor will be
the output on terminals AM and
FC. Same function choices as
H4-01.
Sets terminal AM output
voltage (in percent of 10Vdc)
when selected monitor is at
100% output.*
Sets terminal AM output
voltage (in percent of 10Vdc)
when selected monitor is at 0%
output.*
Selects the signal level of
terminal FM.
0: 0 to 10Vdc
1: -10 to +10Vdc
2: 4 to 20mA*
*Set the analog output jumper
CN15 in the proper position.
Selects the signal level of
terminal AM.
0: 0 to 10Vdc
1: -10 to +10Vdc
2: 4 to 20mA*
*Set the analog output jumper
CN15 in the proper position.
Control Methods
Change
Setting
Factory
V/f
during
Range
Setting
V/f
with
Operation
PG
1 to 48
2
No
A
0.00
to
1.00
Yes
Q
2.50
-10.0
to
0.0%
Yes
A
10.0
1 to 48
3
No
A
0.00
to
0.50
Yes
Q
2.50
-10.0
to
0.0%
Yes
A
10.0
0 to 2
0
No
A
0 to 2
0
No
A
Open
Open
MODBUS
Loop
Flux
Loop
Register
Vector
Vector
Vector
1
2
A
A
A
A
41DH
Q
Q
Q
Q
41EH
A
A
A
A
41FH
A
A
A
A
420H
Q
Q
Q
Q
421H
A
A
A
A
422H
A
A
A
A
423H
A
A
A
A
424H

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents